McAfee® Network Security Platform, công cụ phát hiện và ngăn chặn xâm nhập thế hệ mới (IDPS), giúp phát hiện và chặn các mối đe dọa phần mềm độc hại tinh vi.
Sản phẩm và thông số kỹ thuật chi tiết:
Sensor Hardware Components | NS9500 | |||||
10 Gbps license (1 unit) |
20 Gbps license (1 unit) |
30 Gbps license (1 unit) |
40 Gbps license (2 units) |
60 Gbps license (2 units) |
100 Gbps license (4 units) |
|
Performance | ||||||
Aggregate Performance | 10 Gbps | 20 Gbps | 30 Gbps | 40 Gbps | 60 Gbps | 100 Gbps |
Maximum Throughput (UDP 1512-byte packets) |
Up to 15 Gbps | Up to 25 Gbps | Up to 35 Gbps | Up to 50 Gbps | Up to 70 Gbps | Up to 100 Gbps |
Maximum Concurrent Connections | 10,000,000 | 13,000,000 | 16,000,000 | 26,000,000 | 32,000,000 | 64,000,000 |
Connections per Second | 450,000 | 525,000 | 650,000 | 1,000,000 | 1,300,000 | 2,500,000 |
HTTP Connections per Second | 260,000 | 300,000 | 350,000 | 600,000 | 700,000 | 1,400,000 |
Throughput with SSL Decryption (based on 10% SSL traffic) |
10 Gbps | 18 Gbps | 26 Gbps | 36 Gbps | 52 Gbps | 90 Gbps |
Maximum SSL Flow Count | 1,000,000 | 1,300,000 | 1,600,000 | 2,600,000 | 3,200,000 | 6,400,000 |
SSL Keys Imported | 1,024 | 1,024 | 1,024 | 1,024 | 1,024 | 1,024 |
Number of Virtual IPS Systems | 1,000 | 1,000 | 1,000 | 1,000 | 1,000 | 1,000 |
Maximum DoS Profiles | 5,000 | 5,000 | 5,000 | 5,000 | 5,000 | 5,000 |
ACL Rules | 10,000 | 20,000 | 30,000 | 20,000 | 30,000 | 30,000 |
Ports | ||||||
Fixed 10 Gigabit Ethernet/1 Gigabit Ethernet RJ45 Ports—with internal fail-open |
4 | 4 | 4 | 8 | 8 | 16 |
Fixed 100/40 Gigabit Ethernet Ports | 2 | 2 | 2 | N/A | N/A | N/A |
Network I/O Slots | 2 | 2 | 2 | 4 | 4 | 8 |
Network I/O Modules (nine options) | 2-port QSFP28 100/ QSFP+ 40 GigE module, 4-port 10 GigE/1 GigE SR Optical 50 micron with fail-open, 4-port 10 GigE/1 GigE SR Optical 62.5 micron with fail-open, 4-port 10 GigE/1 GigE LR Optical with fail-open, 4-port (QSFP+) 40 GigE, 2-port (QSFP+) 40 GigE, 8-port (SFP+/SFP) 10 GigE/1 GigE, 6-port (RJ45) 1 GigE (with internal fail-open), or 4-port (RJ45) 10 GigE/1 GigE/100 Mbps (with internal fail-open) |
2-port QSFP28 100/ QSFP+ 40 GigE module, 4-port 10 GigE/1 GigE SR Optical 50 micron with fail-open, 4-port 10 GigE/1 GigE SR Optical 62.5 micron with fail-open, 4-port 10 GigE/1 GigE LR Optical with fail-open, 4-port (QSFP+) 40 GigE, 2-port (QSFP+) 40 GigE, 8-port (SFP+/SFP) 10 GigE/1 GigE, 6-port (RJ45) 1 GigE (with internal fail-open), or 4-port (RJ45) 10 GigE/1 GigE/100 Mbps (with internal fail-open) |
2-port QSFP28 100/ QSFP+ 40 GigE module, 4-port 10 GigE/1 GigE SR Optical 50 micron with fail-open, 4-port 10 GigE/1 GigE SR Optical 62.5 micron with fail-open, 4-port 10 GigE/1 GigE LR Optical with fail-open, 4-port (QSFP+) 40 GigE, 2-port (QSFP+) 40 GigE, 8-port (SFP+/SFP) 10 GigE/1 GigE, 6-port (RJ45) 1 GigE (with internal fail-open), or 4-port (RJ45) 10 GigE/1 GigE/100 Mbps (with internal fail-open) |
2-port QSFP28 100/ QSFP+ 40 GigE module, 4-port 10 GigE/1 GigE SR Optical 50 micron with fail-open, 4-port 10 GigE/1 GigE SR Optical 62.5 micron with fail-open, 4-port 10 GigE/1 GigE LR Optical with fail-open, 4-port (QSFP+) 40 GigE, 2-port (QSFP+) 40 GigE, 8-port (SFP+/SFP) 10 GigE/1 GigE, 6-port (RJ45) 1 GigE (with internal fail-open), or 4-port (RJ45) 10 GigE/1 GigE/100 Mbps (with internal fail-open) |
2-port QSFP28 100/ QSFP+ 40 GigE module, 4-port 10 GigE/1 GigE SR Optical 50 micron with fail-open, 4-port 10 GigE/1 GigE SR Optical 62.5 micron with fail-open, 4-port 10 GigE/1 GigE LR Optical with fail-open, 4-port (QSFP+) 40 GigE, 2-port (QSFP+) 40 GigE, 8-port (SFP+/SFP) 10 GigE/1 GigE, 6-port (RJ45) 1 GigE (with internal fail-open), or 4-port (RJ45) 10 GigE/1 GigE/100 Mbps (with internal fail-open) |
2-port QSFP28 100/ QSFP+ 40 GigE module, 4-port 10 GigE/1 GigE SR Optical 50 micron with fail-open, 4-port 10 GigE/1 GigE SR Optical 62.5 micron with fail-open, 4-port 10 GigE/1 GigE LR Optical with fail-open, 4-port (QSFP+) 40 GigE, 2-port (QSFP+) 40 GigE, 8-port (SFP+/SFP) 10 GigE/1 GigE, 6-port (RJ45) 1 GigE (with internal fail-open), or 4-port (RJ45) 10 GigE/1 GigE/100 Mbps (with internal fail-open) |
10 Gigabit Ethernet | Up to 20 | Up to 20 | Up to 20 | Up to 40 | Up to 40 | Up to 80 |
40 Gigabit Ethernet | Up to 10 | Up to 10 | Up to 10 | Up to 16 | Up to 16 | Up to 32 |
100 Gigabit Ethernet | Up to 6 | Up to 6 | Up to 6 | Up to 8 | Up to 8 | Up to 16 |
Dedicated Response Ports (RJ45) | 1 (10G/1G) | 1 (10G/1G) | 1 (10G/1G) | 2 (10G/1G) | 2 (10G/1G) | 4 (10G/1G) |
Dedicated Management Ports (RJ45) | 1 (10G/1G) | 1 (10G/1G) | 1 (10G/1G) | 2 (10G/1G) | 2 (10G/1G) | 4 (10G/1G) |
Physical | ||||||
Dimensions | 17 ¼” (W) x 29 1/16” (D) x 1 ¾” (H) |
17 ¼” (W) x 29 1/16” (D) x 1 ¾” (H) |
17 ¼” (W) x 29 1/16” (D) x 1 ¾” (H) |
2 units each measure 17 ¼” (W) x 29 1/16” (D) x 1 ¾” (H) |
2 units each measure 17 ¼” (W) x 29 1/16” (D) x 1 ¾” (H) |
4 units each measure 17 ¼” (W) x 29 1/16” (D) x 1 ¾” (H) |
Weight | 28.55 lbs | 28.55 lbs | 28.55 lbs | 2x 28.55 lbs | 2x 28.55 lbs | 4x 28.55 lbs |
Storage | 2x 240 GB M.2 (SW RAID) |
2x 240 GB M.2 (SW RAID) |
2x 240 GB M.2 (SW RAID) |
4x 240 GB M.2 (SW RAID) |
4x 240 GB M.2 (SW RAID) |
8x 240 GB M.2 (SW RAID) |
Maximum Power Consumption | 598W | 2x 598W | 2x 598W | 4x 598W | ||
DC Power Available | Optional | |||||
Spare Power Supply | Included | |||||
Power | 100–240 VAC (50/60Hz) | |||||
Temperature | 0° C to 35° C (operating) -40° C to 70° C (non-operating) | |||||
Relative Humidity (non-condensing) | Operational: 10% to 90% Non-operational: 5% to 95% |
|||||
Altitude | 0 to 10,000 feet | |||||
Product Regulatory Compliance | ||||||
Safety Certification | UL 60950-1, UL 62368-1 (USA); CSA 22.2.No. 60950-1, CSA 22.2 No. 62368-1 (Canada); EN 60950-1, EN 62368-1 (Europe); CNS 14336-1 (Taiwan); GB 4943.1 (China) IEC 60950-1, IEC 62368-1 (International)—CB Scheme certificate and test report covering all applicable country deviations; IEC 60825 and 21CFR1040 |
|||||
EMI Certification | FCC Part 15 Subpart B Class A (USA); CAN ICES-3 Class A (Canada); EN 55032, EN 55024, EN 55035, EN61000-3-2, EN61000-3-3 (Europe and International) KN32 and KN35 (South Korea); VCCI 32-1 (Japan); AS/NZS CISPR 32 (Australia and New Zealand); CNS 13438 (Taiwan); GB 9254-2008 and GB 17625.1 (China) |
|||||
ROHS Compliance | Restriction of Hazardous Substances Compliance per applicable directives and standards (Europe, China, Taiwan, and International) |
Sensor Hardware Components | NS7500 | ||
3 Gbps license (1 unit) |
5 Gbps license (1 unit) |
7.5 Gbps license (1 unit) |
|
Performance | |||
Aggregate Performance | 3 Gbps | 5 Gbps | 7.5 Gbps |
Maximum Throughput (UDP 1512-byte packets) |
Up to 6 Gbps | Up to 9 Gbps | Up to 12 Gbps |
Maximum Concurrent Connections | 4,000,000 | 7,000,000 | 10,000,000 |
Connections per Second | 200,000 | 225,000 | 250,000 |
HTTP Connections per Second | 115,000 | 140,000 | 170,000 |
Throughput with SSL Decryption (based on 10% SSL traffic) |
2.7 Gbps | 4.5 Gbps | 6.7 Gbps |
Maximum SSL Flow Count | 400,000 | 700,000 | 1,000,000 |
SSL Keys Imported | 1,024 | 1,024 | 1,024 |
Number of Virtual IPS Systems | 1,000 | 1,000 | 1,000 |
Maximum DoS Profiles | 5,000 | 5,000 | 5,000 |
ACL Rules | 3,000 | 3,000 | 5,000 |
Ports | |||
Fixed Gigabit Ethernet—Copper Ports (internal fail-open) |
8 | 8 | 8 |
Fixed 10 GigE/1 GigE (SFP+) Ports | 2 | 2 | 2 |
Fixed 40 Gigabit Ethernet | — | — | — |
Network I/O Slots | 2 | 2 | 2 |
Network I/O Modules (six options) | 4-port 10 GigE/1 GigE SR Optical 50 micron with fail-open, 4-port 10 GigE/1 GigE SR Optical 62.5 micron with fail-open, 4-port 10 GigE/1 GigE LR Optical with fail-open, 8-port (SFP+/SFP) 10 GigE/1 GigE, 6-port (RJ45) 1 GigE with internal fail-open, or 4-port (RJ45) 10 GigE/1 GigE/100 Mbps (with internal fail-open) |
||
10 Gigabit Ethernet | Up to 18 | Up to 18 | Up to 18 |
40 Gigabit Ethernet | — | — | — |
Dedicated Response Ports (RJ45) | 1 (10G/1G) | 1 (10G/1G) | 1 (10G/1G) |
Dedicated Management Ports (RJ45) | 1 (10G/1G) | 1 (10G/1G) | 1 (10G/1G) |
Physical | |||
Dimensions | 17.31” (W) x 1.75” (H) x 29.13” (D) | 17.31” (W) x 1.75” (H) x 29.13” (D) | 17.31” (W) x 1.75” (H) x 29.13” (D) |
Weight | 25.5 lbs. | 25.5 lbs. | 25.5 lbs. |
Storage | Solid State 240 GB M.2 | Solid State 240 GB M.2 | Solid State 240 GB M.2 |
Maximum Power Consumption | 300W | 300W | 300W |
DC Power Available | Optional | Optional | Optional |
Spare Power Supply | Included | Included | Included |
Power | 100–240 VAC (50/60Hz) | ||
Temperature | 0° C to 35° C (operating) -40° C to 70° C (non-operating) | ||
Relative Humidity (non-condensing) | Operational: 10% to 90% Non-operational: 5% to 95% |
||
Altitude | 0 to 10,000 feet | ||
Product Regulatory Compliance | |||
Safety Certification | UL 60950-1, UL 62368-1 (USA); CSA 22.2.No. 60950-1, CSA 22.2 No. 62368-1 (Canada); EN 60950-1, EN 62368-1 (Europe); CNS 14336-1 (Taiwan); GB 4943.1 (China) IEC 60950-1, IEC 62368-1 (International)—CB Scheme certificate and test report covering all applicable country deviations; IEC 60825 and 21CFR1040 |
||
EMI Certification | FCC Part 15 Subpart B Class A (USA); CAN ICES-3 Class A (Canada); EN 55032, EN 55024, EN61000-3-2, EN61000-3-3 (Europe and International) KN32 and KN35 (South Korea); VCCI 32-1(Japan); AS/NZS CISPR 32 (Australia and New Zealand); CNS 13438 (Taiwan); GB 9254-2008 and GB 17625.1 (China) |
||
ROHS Compliance | Restriction of Hazardous Substances Compliance per applicable directives and standards (Europe, China, Taiwan, and International) |
Sensor Hardware Components | NS3500 | NS3200 | NS3100 | |||
With 10.1 Update 2 release & earlier |
With 10.1 Update 3 release & later |
With 10.1 Update 2 release & earlier |
With 10.1 Update 3 release & later |
With 10.1 Update 2 release & earlier |
With 10.1 Update 3 release & later |
|
Performance | ||||||
Aggregate Performance | 200 Mbps | 750 Mbps | 200 Mbps | 750 Mbps | 100 Mbps | 750 Mbps |
Maximum Throughput (UDP 1512-byte packets) |
Up to 1 Gbps | Up to 1 Gbps | Up to 1 Gbps | Up to 1 Gbps | Up to 600 Mbps | Up to 1 Gbps |
Maximum Concurrent Connections | 80,000 | 100,000 | 80,000 | 100,000 | 40,000 | 100,000 |
Connections Established per Second | 25,000 | 25,000 | 20,000 | 25,000 | 15,000 | 25,000 |
HTTP Connections per Second (using 1 GET with 5000 HTTP response) |
15,000 | 15,000 | 15,000 | 15,000 | 12,000 | 15,000 |
Throughput with SSL Decryption (based on 10% SSL traffic) |
— | — | — | |||
Maximum SSL Flow Count | — | — | — | |||
SSL Keys Imported | — | — | — | |||
Number of Virtual IPS Systems | 32 | 32 | 16 | |||
Maximum DoS Profiles | 128 | 128 | 128 | |||
ACL Rules | 1,000 | 1,000 | 1,000 | |||
Ports | ||||||
Fixed Gigabit Ethernet—Copper Ports (internal fail-open) |
4 | 8 | 8 | |||
Fixed 1 GigE (SFP) Ports | — | — | — | |||
Fixed 10 GigE/1 GigE (SFP+) Ports (external passive fail-open kit support) |
— | — | — | |||
Fixed 40 Gigabit Ethernet | — | — | — | |||
Network I/O Slots | — | — | — | |||
Network I/O Modules | — | — | — | |||
10 Gigabit Ethernet | — | — | — | |||
40 Gigabit Ethernet | — | — | — | |||
Dedicated Response Ports (RJ45) | — | 1 (1G/100M) | 1 (1G/100M) | |||
Dedicated Management Ports (RJ45) | 1x 10/100/1000 Mbps | 1 (1G/100M) | 1 (1G/100M) | |||
Physical | ||||||
Dimensions | 1RU Rack Mountable 9.45” (W) x 1.73” (H) x 6.54” (D) |
1RU Rack Mountable 17.375” (W) x 1.75” (H) x 11.0” (D) |
1RU Rack Mountable 17.375” (W) x 1.75” (H) x 11.0” (D) |
|||
Weight | 2.65 lbs | 8.1 lbs. | 8.1 lbs. | |||
Storage | 32 GB Compact Flash | Solid State 30 GB | Solid State 30 GB | |||
Maximum Power Consumption | 30W | 100W | 100W | |||
DC Power Available | — | — | — | |||
Spare Power Supply | — | — | — | |||
Power | 100–240 VAC (50/60Hz) | 100–240 VAC (50/60Hz) | ||||
Temperature | 0° C to 35° C (operating) -40° C to 70° C (non-operating) |
0° C to 35° C (operating) -40° C to 70° C (non-operating) |
||||
Relative Humidity (non-condensing) | Operational: 10% to 90% Non-operational: 5% to 95% |
Operational: 10% to 90% Non-operational: 5% to 95% |
||||
Altitude | 0 to 10,000 feet | 0 to 10,000 feet | ||||
Product Regulatory Compliance | ||||||
Safety Certification | UL 60950-1, UL 62368-1 (USA); CSA 22.2.No. 60950-1, CSA 22.2 No.62368-1 (Canada); EN 60950-1, EN 62368-1 (Europe); CNS 14336-1 (Taiwan); GB 4943.1 (China) IEC 60950-1, IEC 62368-1 (International)— CB Scheme certificate and test report covering all applicable country deviations |
UL 60950-1, UL 62368-1 (USA); CSA 22.2.No. 60950-1, CSA 22.2 No. 62368-1 (Canada); EN 60950-1, EN 62368-1 (Europe); CNS 14336-1 (Taiwan); GB 4943.1 (China) IEC 60950-1, IEC 62368-1 (International)—CB Scheme certificate and test report covering all applicable country deviations; IEC 60825 and 21CFR1040 |
||||
EMI Certification | FCC Part 15 Subpart B Class B (USA); CAN ICES-3 Class B (Canada); EN 55032, EN 55024, EN55035, EN61000-3-2, EN61000-3-3 (Europe and International) KN32 and KN35 (South Korea); VCCI Class B (Japan); AS/NZS CISPR 32 (Australia and New Zealand); CNS 13438 (Taiwan); GB 9254-2008 and GB 17625.1 (China) |
FCC Part 15 Subpart B Class A (USA); CAN ICES-3 Class A (Canada); EN 55022, EN 55032, EN 55024, EN61000-3-2, EN61000-3-3 (Europe and International) KN32 and KN24 (South Korea); VCCI Class A (Japan); AS/NZS CISPR 32 (Australia and New Zealand); CNS 13438 (Taiwan); GB 9254-2008 and GB 17625.1 (China) |
||||
ROHS Compliance | Restriction of Hazardous Substances Compliance per applicable directives and standards (Europe, China, Taiwan, and International) |
Restriction of Hazardous Substances Compliance per applicable directives and standards (Europe, China, Taiwan, and International) |
Sensor Hardware Components | NS7350 | NS7250 | NS7150 |
Performance | |||
Aggregate Performance | 5 Gbps | 3 Gbps | 1.5 Gbps |
Maximum Throughput (UDP 1512-byte packets) |
Up to 10 Gbps | Up to 8 Gbps | Up to 5 Gbps |
Maximum Concurrent Connections | 10,000,000 | 5,000,000 | 3,000,000 |
Connections per Second | 225,000 | 200,000 | 135,000 |
HTTP Connections per Second | 135,000 | 128,000 | 115,000 |
Throughput with SSL Decryption (based on 10% SSL traffic) |
5 Gbps | 3 Gbps | 1.5 Gbps |
Maximum SSL Flow Count | 500,000 | 400,000 | 250,000 |
SSL Keys Imported | 1,024 | 1,024 | 1,024 |
Number of Virtual IPS Systems | 1,000 | 1,000 | 1,000 |
Maximum DoS Profiles | 5,000 | 5,000 | 5,000 |
ACL Rules | 5,000 | 3,000 | 3,000 |
Ports | |||
Fixed Gigabit Ethernet—Copper Ports (internal fail-open) |
8 | 8 | 8 |
Fixed 10 GigE/1 GigE (SFP+) Ports | 2 | 2 | 2 |
Fixed 40 Gigabit Ethernet | — | — | — |
Network I/O Slots | 2 | 2 | 2 |
Network I/O Modules (six options) | 4-port 10 GigE/1 GigE SR Optical 50 micron with fail-open, 4-port 10 GigE/1 GigE SR Optical 62.5 micron with fail-open, 4-port 10 GigE/1 GigE LR Optical with fail-open, 8-port (SFP+/SFP) 10 GigE/1 GigE, 6-port (RJ45) 1 GigE with internal fail-open, or 4-port (RJ45) 10 GigE/1 GigE/100 Mbps (with internal fail-open) |
||
10 Gigabit Ethernet | Up to 18 | Up to 18 | Up to 18 |
40 Gigabit Ethernet | — | — | — |
Dedicated Response Ports (RJ45) | 1 (10G/1G) | 1 (10G/1G) | 1 (10G/1G) |
Dedicated Management Ports (RJ45) | 1 (10G/1G) | 1 (10G/1G) | 1 (10G/1G) |
Physical | |||
Dimensions | 17.31” (W) x 1.75” (H) x 29.13” (D) | 17.31” (W) x 1.75” (H) x 29.13” (D) | 17.31” (W) x 1.75” (H) x 29.13” (D) |
Weight | 28 lbs. | 28 lbs. | 28 lbs. |
Storage | Solid State 240 GB | Solid State 240 GB | Solid State 240 GB |
Maximum Power Consumption | 300W | 300W | 300W |
DC Power Available | Optional | Optional | Optional |
Spare Power Supply | Included | Included | Included |
Power | 100–240 VAC (50/60Hz) | ||
Temperature | 0° C to 35° C (operating) -40° C to 70° C (non-operating) | ||
Relative Humidity (non-condensing) | Operational: 10% to 90% Non-operational: 5% to 95% |
||
Altitude | 0 to 10,000 feet |